DIGICONTROL Sensors and Monitors

F-AFF-U

Outside humidity sensor

The outside humidity sensor measures the relative humidity outside and converts these measurements into standard signals.

Sensor:Condensation-proof humidity–temperature sensor transmitter SHT 75, Sensor protection sintered bronze filter

Outputs: 0...10 V DC correspond 0...100 % rh

Tender Text
EC Declaration of conformity

F-AFTF-T

Outdoor humidity and temperature sensor

The F-AFTF-T is used for measuring humidity and temperature outdoors. As delivered, the sensor is designed to measure temperature and relative humidity. Alternatively, absolute humidity, enthalpy or dew point can also be measured.

F-AFTF-U

Outdoor humidity and temperature sensor

The outdoor humidity and temperature sensor measures the relative humidity and temperature outdoors and converts these measured values into standard signals.

Sensor: Condensation-proof humidity–temperature sensor transmitter SHT 75, Sensor protection sintered bronze filter

Outputs:
■ Temperature: 0...10 V in measuring range from -20...+80°C
■ Humidity: 0...10 V corresponds to 0...100 % rh.

Tender Text
EC Declaration of conformity

F-AGF-T

Screw-in temperature sensor

Screw-in immersion sensor for measuring especially higher temperatures in liquid and gaseous media of heating, ventilation, and air conditioning systems as well as in exhaust gas systems. Equipped with neck tube. Designed for connection to controller and display systems.

F-AHF

Outdoor brightness sensor

The device is used for the measuring the illumination. The measuring signal of the brightness sensor is converted into the standard signal 0...10 V and output.

Sensor: Transparent cap / glass

Outputs:
■ Illuminance: 0...10 Volt

Measuring range: 0...500 kLux, 0...1 kLux, 0...2 kLux, 0...5 kLux, 0...20 kLux (default), 0...60 kLux

Tender Text
EC Declaration of conformity

F-AHF-T

Outdoor brightness sensor

The F-AHF-T is used to measure the illuminance. The brightness sensor is optimally adapted to the spectral sensitivity of the human eye.

F-ALTF-T

Contact temperature sensor

The F-ALTF-T in the hinged cover housing USE for measuring the temperature on pipes and curved surfaces. The measuring element is pressed onto the measuring surface by a spring mechanism to achieve direct contact and fast response. Designed for connection to controller and display systems.

F-ALTF221

Mounted temperature sensor

This mounted temperature sensor can be attached to pipelines using straps for non-invasive measurement of liquid and gas temperatures.

Sensor: Pt1000

Measuring range: -35...+110 °C

Tender Text
EC Declaration of conformity

F-ATF-T

Outdoor temperature sensor with optional sun/rain protection

The sensor F-ATF-T in the hinged cover housing USE is suitable for outdoor temperature measurement, in refrigerated warehouses and greenhouses as well as in production halls and warehouses.

F-ATF121B

Outside temperature sensor with optional radiation protection plate

The outside temperature sensor F-ATF121B convectively measures the air temperature using primary sensors installed in a plastic casing.

Sensor: Pt1000

Measuring range: -35...+60 °C

Tender Text
EC Declaration of conformity

F-BW/LS360/500-1

Combined room brightness and motion sensor

The device is used to measure the illuminance. The measuring signal of the brightness sensor is converted into the standard signal 0...10 V and put out.

Sensor: Photodiode with filter, glass cover, hermetically sealed sensor

Outputs: 0...10 V

Measuring range: 500 Lux / 1 kLux / 20 kLux, factory setting 500 Lux

Tender Text
EC Declaration of conformity

F-BW360-1

Room motion sensor

The device is used to detect persons at a distance of up to 10 meters.

Sensor: PIR motion sensor MTS 10/360, hermetically sealed sensor

Outputs: Potential-free changeover contact, max. 48 V, 1 A

Tender Text
EC Declaration of conformity

F-ClimaSens-D

Climate sensor

The climate sensor F-ClimaSens-D measures the parameters of rainfall (yes/no), brightness (East/South/West) and twilight.

Tender Text
EC Declaration of conformity

F-ClimaSens-DTF

Climate sensor

The climate sensor F-ClimaSens-DTF measures the parameters of rainfall (yes/no), brightness (East/South/West), temperature, air humidity and twilight.

Tender Text
EC Declaration of conformity

F-ClimaSens-DW

Climate sensor

The climate sensor F-ClimaSens-DW measures the parameters of wind speed, rainfall (yes/no), brightness (East/South/West) and twilight.

Tender Text
EC Declaration of conformity

F-ClimaSens-DWTF

Climate sensor

The climate sensor F-ClimaSens-DWTF measures the parameters of wind speed, rainfall (yes/no), brightness (East/South/West), temperature, air humidity and twilight.

Tender Text
EC Declaration of conformity

F-DDM

Differential pressure measuring transducers

The calibrateable compact pressure sensors of the F-DDM... series are equipped with 8 switchable measuring ranges, 2 switchable output signals and with or without optional display and are used for measuring above-atmospheric, below-atmospheric, or differential pressures in air.

Outputs: 0...10 V / 4...20 mA

Tender Text
EC Declaration of conformity

F-DDML...-T

Differential pressure transmitter

The differential pressure transmitter with 8 adjustable measuring ranges and the analogue output signals 0...10 V and 4...20 mA is used to detect differential pressures of air and other non-flammable and non-aggressive gases. Possible applications are the monitoring of air filters, fans, industrial cooling air circuits and flows in ventilation ducts.

F-DDMW-T

Differential pressure transmitter for liquid media

The differential pressure transmitter F-DDMW-T measures the differential pressure in liquid media. Typical areas of application are the supply and return in heating systems and the monitoring of filters and compressors.

F-DDPTM

Differential pressure transmitter for gaseous or liquid media

The F-DDPTM... is used to measure differential pressures in air, liquids and oils.

Sensor: Stainless steel, no oil reservoir, maintenance-free

Outputs: 0...10 V

Tender Text
EC Declaration of conformity

F-DMU...-T

Pressure transmitter

The pressure transmitter is used to measure the pressure in liquid media in air-conditioning, heating, and water technology. Suitable for plants with refrigerants.

F-ETF521

Pipeline temperature sensor

The type ETF pipeline sensor can be installed in pipeline networks, containers or exhaust ducts, depending on the installed sensor, in the range of -35 to +600 °C.

Sensor: Pt1000

Measuring range: -35...+600 °C

Tender Text
EC Declaration of conformity

F-FKATF121

Rapid duct temperature sensor

The rapid duct temperature sensor is designed for quick temperature control in air ventilation ducts.

Sensor: Pt1000

Measuring range: -35...+150 °C

Tender Text
EC Declaration of conformity

F-KATF...-T

Duct/immersion temperature sensor

The duct/immersion sensor is used for temperature measurement in gaseous media of heating, ventilation, and air conditioning systems. In combination with an immersion sleeve, it is also suitable for measuring in liquid media (e.g., piping systems).

F-KCO2T-T

Duct air quality sensor

The duct air quality sensor is used to detect the CO2 content. An analogue 0...10 V output is available for direct connection to a DDC or a monitoring system.

F-KCO2T1

CO2 and temperature measuring transmitter for duct mounting

The measuring transmitter F-KC02T1 is designed for duct mounting and enables an accurate and long-term stable measurement of the CO2 concentration and temperature.

Sensor:
■ Measuring rate approx. 15 s
■ 2 beam infrared cell (non-dispersive infrared technology (NDIR))

Outputs: 0...10 V

Measuring range:
■ CO2: 0...2000 ppm
■ Temperature: 0...50 °C

Tender Text
EC Declaration of conformity

F-KFTF-20U

Duct humidity/temperature for extreme conditions

The duct humidity sensor measures the relative humidity and the temperature of the air and other non-aggressive gases and converts these measurements into standard signals.

Sensor: Condensation-proof humidity–temperature sensor transmitter SHT 75, Sensor protection sintered bronze filter

Outputs:
■ Humidity: 0...10 V corresponds 0...100 % rh.
■ Temperature: 0...10 V corresponds 0...50 °C

Measuring range:
■ Temperature: 0...50 °C,
■ Humidity: 0...100 % rh.

Tender Text
EC Declaration of conformity

F-KFTF-S

Duct humidity and temperature sensors

Calibratable duct humidity- / temperature sensor measures the relative humidity and / or the temperature of the air and converts the measurands into a standard signal of 0-10 V.

Sensor: Digital humidity sensor with integrated temperature sensor, plastic sinter filter, diameter = 16 mm, length = 35 mm, exchangeable

Outputs: 0...10 V

Measuring range:
■ Temperature: -35...+35 °C, -35...+75 °C, 0...+50 °C, 0...+80 °C
■ Humidity: 0...100 % rF

Tender Text
EC Declaration of conformity

F-KFTF-T

Duct sensor for humidity and temperature

The duct humidity sensor is used to measure humidity and temperature in gaseous media of heating, ventilation, and air-conditioning plants (e.g., in supply/exhaust air plants).

F-KLQ-T

Duct air quality sensor

The duct air quality sensor is used to detect the VOC content. An analogue 0...10 V output is available for direct connection to a DDC or a monitoring system.

F-KLQ1

Duct air quality sensor

This measurement converter is used to measure air quality. It converts the measurement signal to the standard signal of 0 to 10 volts.

Sensor: Sintered filter, sensor in the housing, chemical mixed gas sensor

Outputs: 0...10 V (default)

Measuring range:
■ Air quality: calibration for normal loads

Tender Text
EC Declaration of conformity

F-KLSF-T

Temperature and airflow transducer

The temperature and airflow transmitter is used to measure and monitor airflows in supply / extract air plants, on fans, control dampers and electric heating registers.

F-KTF-T

Cable temperature sensor

The cable sensor is used for temperature measurement in gaseous media of heating, ventilation, and air conditioning systems (e.g., in supply air/exhaust air ducts). In combination with an immersion sleeve, it is also suitable for measuring in liquid media (e.g. piping systems).

F-KTF121

Cable temperature sensor

This temperature sensor, consisting of a connection cable and a small VA protective sleeve, is designed for any measurement of temperatures.

Sensor: Pt1000

Measuring range: -35...+150 °C

Tender Text
EC Declaration of conformity

F-LS-T

Ceiling multisensor

The brightness sensor for ceiling installation detects the amount of indoor or outdoor light in living reems, offices, or workplaces. The brightness sensor is optimally adapted to the spectral sensitivity of the human eye and is used together with downstream controller systems for demand-responsive light or sun protection control. The remote sensor is connected to the connection housing via a conventional RJ45 cable and can thus be easily mounted in places that are difficult to access. If 2 sensors are used, the average, min or max value from both brightness signals can be output in addition to the individual values.

F-LS500-1

Room brightness sensor

The device is used to measure the illuminance. The measuring signal of the brightness sensor is converted into the standard signal 0...10 V and put out.

Sensor: Photodiode with filter, glass cover, hermetically sealed sensor

Outputs: 0...10 V

Measuring range: 500 Lux / 1 kLux / 20 kLux, factory setting 500 Lux

Tender Text
EC Declaration of conformity

F-MWTF...-T

Mean value temperature sensor

The duct mean value sensor in the hinged cover housing is used to record the average temperature (mean value) for temperature stratification in gaseous media. The sensor records the temperature value evenly over the entire length.

F-MWTF121PE

Mean value temperature sensor

Mean value temperature sensor is used to measure the average temperature of the medium in pipes and ducts.

Sensor: Pt1000

Tender Text
EC Declaration of conformity

F-RB-T

Motion detector

The F-RB-T motion detector detects movements of people and switches a relay contact for lighting control or for lowering the temperature of empty rooms.

F-RBH-T

Ceiling multisensor 360°

The F-RBH-T ceiling multisensor with motion detection and light measurement is used to implement constant light control in indoor spaces. By detecting the presence of people, energy-efficient light control or temperature reduction iin empty rooms can be implemented. Due to its flat design, the device is suitable for discreet installation in suspended ceilings.

F-RCO2T-T

Room CO2 and temperature sensor

The F-RCO2T-T is used to detect the CO2 content and the temperature. The maintenance-free sensor creates the conditions for a pleasant indoor climate. Typical areas of application are schools, office buildings, hotels, or cinemas.

F-RCO2T2

Room CO2 and temperature sensor

By the combination of CO2 and temperature measurement in a modern, assembly friendly case the measurand transducer F-RCO2T1 sets new standards in HVAC technology.

Sensor: 2 beam infrared cell (non-dispersive infrared technology (NDIR))

Outputs: 0...10 V

Measuring range:
■ CO2: 0...2000 ppm
■ Temperature: 0...50 °C

Tender Text
EC Declaration of conformity

F-RCO2TF-T

Room, CO2, temperature, and humidity sensors

The F-RCO2TF-T is used to detect the CO2 content as well as the temperature and room humidity. The maintenance-free sensor creates the conditions for a pleasant room climate. Typical areas of applications are schools, office buildings, hotels, or cinemas.

F-RCO2TF1

Room CO2, humidity and temperature sensor

By combining the measurement of CO2, relative humidity (rh) and temperature (T) and by having a modern and easy to install housing, the F-RC02TF1 sets a new standard in the field of HVAC (heating/ ventilation/ air conditioning) technology.

Sensor: 2 beam infrared cell (non-dispersive infrared technology (NDIR))

Outputs: 0...10 V (corresponds to 0...100 % rh.)

Measuring range:
■ CO2: 0...2000 ppm
■ Temperature: 0...50 °C
■ Humidity: 10...90 % rh.

Tender Text
EC Declaration of conformity

F-RFTF-20U

Room humidity/temperature sensor for extreme conditions

The humidity/temperature sensor measures the relative humidity and the temperature of the air and other non-aggressive gases and converts these measurements into standard signals.

Sensor: Sintered bronze filter

Outputs:
■ Humidity: 0...10 V DC corresponds to 0...100 % rh.
■ Temperature: 0...10 V DC corresponds to 0...50 °C

Measuring range:
■ Temperature: 0...50 °C
■ Humidity: 0...100 % rh.

Tender Text
EC Declaration of conformity

F-RFTF-E

Room humidity and temperature sensor

The room humidity and temperature measuring transmitter F-RFTF-E is the ideal solution for indoor applications in the field of HVAC (heating, ventilation and air-conditioning) technology.

Outputs: 0...10 V

Measuring range:
■ Temperature: 0...50 °C
■ Humidity: 0...95 % rh.

Tender Text
EC Declaration of conformity

F-RFTF-T

Room sensor for temperature and humidity

The F-RFTF-T is used to detect the room temperature and the room humidity. The maintenance-free sensor creates the prerequisite for a pleasant room climate. Typical areas of applications are schools, office buildings, hotels, and cinemas.

F-RLQ

Room air quality sensor

The measurement converter is used to measure air quality. It converts the measurement signal to the standard signal of 0 to 10 volts.

Sensor: Sensor in the housing, chemical mixed gas sensor

Outputs: 0...10 V

Measuring range:
■  Air quality: calibration for normal loads

Tender Text
EC Declaration of conformity

F-RLQ-T

Room air quality sensor

The F-RLQ-T is used to detect the mixed gas content. The maintenance-free sensor creates the prerequisite for a pleasant room climate. Typical areas of applications are schools, office buildings, hotels, cinemas or similar.

F-ROF...-T

Duct/immersion temperature sensor

The duct/immersion sensor is suitable for temperature measurement in gaseous media of heating, ventilation, and air conditioning plants. In combination with an immersion sleeve, it is also suitable for measurement in liquid media (e.g., piping systems).

F-ROF121

Flexible submersible temperature sensor

The flexible submersible sensor is used for temperature measurement in pipelines and containers when using additional thermowells.

Sensor: Pt1000

Measuring range: -35...+150 °C

Tender Text
EC Declaration of conformity

F-RTF-T

Room temperature sensor

The living room sensor is used to detect the room temperature. The sensor creates the prerequisite for a pleasant room climate and well-being. Typical areas of applications are school, office buildings, hotels, or cinemas.

F-RTF121

Room temperature sensor

Room temperature sensors convectively measure the air temperature by using their internal primary sensors through the housing vent slots or via an external protection tube (diameter 2 mm).

Sensor: Pt1000

Measuring range: -35...+60 °C

Tender Text
EC Declaration of conformity

F-RTF321

Room temperature sensor setpoint-potentiometer

Room temperature sensors convectively measure the air temperature by using their internal primary sensors through housing vent slots with built-in sensors.

Sensor: Pt1000

Measuring range: -35...+60 °C

Tender Text
EC Declaration of conformity

F-RTFS-T

Room control unit temperature

The room control unit with setpoint adjuster is used to detect the room temperature. The sensor creates the prerequisite for a pleasant room climate and well-being. Typical areas of application are schools, office buildings, hotels, or cinemas.

F-SPT-U

Pressure measurement transducer for gaseous or liquid media

The F-SPT-U... pressure measurement transducer is used to measure pressure (relative pressure to the external atmosphere or closed reference) in gaseous or liquid media.

Sensor: Stainless steel membrane, CrNiCuNb 17-4 PH stainless steel, no O-ring, no oil

Outputs: 0...10 V

Tender Text
EC Declaration of conformity

R-BCP

Pressure switch

The BCP type is a series of dedicated pressure switches for safety and pressure monitoring of steam and hot water boilers.

Tender Text
EC Declaration of conformity

R-BCPxH

Pressure relief valve for rising pressure

The BCP type is a series of dedicated pressure switches for safety and pressure monitoring of steam and hot water boilers.

Tender Text
EC Declaration of conformity

R-BCPxL

Pressure relief valve for falling pressure

The BCP type is a series of dedicated pressure switches for safety and pressure monitoring of steam and hot water boilers.

Tender Text
EC Declaration of conformity

R-DDS...-T

Differential pressure switch

Adjustable differential pressure switch for monitoring the differential pressure of air and other non-flammable and non-aggressive gases. Possible applications are the monitoring of air filters, fans, industrial cooling air circuits and flows in ventilation ducts.

R-DRIW-E16

V-Belt monitor

The V-belt monitor R-DRIW-E16 is used to monitor rotary movements (underspeeding) of V-belt driven drive shafts.

R-FW

Frost protection thermostat, mechanical, single-stage, with switching output

Mechanical frost protection thermostat with switching output, fully-active sensor rod, with automatic reset, in various capillary tube lengths. The frost protection thermostat is used for air-side temperature monitoring of heating registers against freezing up and to avoid frost damages, e. g. in ventilation and air conditioning ducts.

Outputs:
■ Switching capacity: 10 (2) A, AC 250 V; signal voltages < 24V can also be switched due to the gold-plated contacts

Tender Text
EC Declaration of conformity

R-FW...-T

Frost protection thermostat

The frost protection thermostat is used for air-side temperature monitoring of water/air heaters in ventilation and air-conditioning plants to prevent frost damage. It has a small switching differential and high reproducibility. The reset is automatic.By switching the frost protection thermostat, the following frost protection measures can be triggered, for example:- Fan OFF- Fresh air damper CLOSED- Air heating valve 100 % OPEN- Heat pump ON- Chiller (compressor) and humidifier OFF- Triggering of the frost hazard message optically and/or acoustically.

R-FWS...-1

Two-phase frost thermostat with continuous and switching output

Electronic forst protection thermostat with switching relay output, continuous temperature, and valve output (summation output 0-10 V) as well as control and cascading input (0-10 V), in impact-resistant plastic housing wiht quick-locking screws, with display as standard, with fully active sensor rod made of copper.

Outputs:
■ 1x 0-10 V temperature (corresponds to 0...+15 °C)
■ 1x 0-10 V valve (frost signal with control voltage and cascading)
■ 1x potentail free changeover contact (24 V), setting range 0...+15 °C

Measuring range: 0...+15 °C

Tender Text
EC Declaration of conformity

R-KH

Duct-hygrostat

Suitable for closed- loop control and monitoring of the relative humidity in ventilation and air conditioning ducts, climatic chambers, swimming pools, greenhouses, etc. and for the open-loop Control of humidifcation and dehumidifcation plants. It is not suitable for aggressive gases.

Outputs: Switching, 1-level

Tender Text
EC Declaration of conformity

R-KH-T

Duct hygrostat for controlling the relative humidity

The duct hygrostat (two-point controller) is used to control relative humidity. Possible applications are almost everywhere where humidity has to be monitored and controlled, such as in ventilation and air-conditioning systems, climate cabinets, air humidifiers and dehumidifiers, office and computer rooms, storage for food and luxury foodstuffs, cold rooms for fruit and vegetables, greenhouses of horticultural businesses, textile industry, paper and printing industruy, film industry, hospitals and similar.

R-KLSW-T

Temperature and airflow transducer

The temperature and airflow transmitter is used to measure and monitor airflows in supply/extract air systems, on fans, control dampers and electric heating registers.

R-KLSW10

Air-flow sensor

The air-flow sensor is suitable for monitoring and controlling air- flows in ducts, fans, butterfly valves, for flow-dependent monitoring of humidifiers and electrical heat registers in accordance with DIN 57100 part 420 or for the application in connection with DDC systems. The device has temperature compensation.

Outputs: 0-10 V (relative)

Tender Text
EC Declaration of conformity

R-KLSW4

Air-flow sensor

The air-flow sensor is suitable for monitoring and controlling air- flows in ducts, fans, butterfly valves, for flow-dependent monitoring of humidifiers and electrical heat registers in accordance with DIN 57100 part 420 or for the application in connection with DDC systems. The device has temperature compensation.

Tender Text
EC Declaration of conformity

R-KRM-X

Smoke switch for air duct monitoring with VDC recognition

The duct smoke detector R-KRM-X... was developed for smoke detection in ventilation ducts. It is a combination of a smoke detector and an adapter system, whose measuring tube and housing have been specially customised for an optimum air flow through the smoke detector.

Outputs:
■ Relay outputs: potential-free
■ Alarm relay locked: 1 changeover contact, 8 A, 250 V AC or 24 V DC / 1 normally closed contact, 8 A, 250 V AC or 24 V DC
■ Pollution relay: 1 NC contact, 6 A, 250 V AC or 24 VDC

Tender Text
EC Declaration of conformity

R-KRM-X-DZ

Smoke switch for duct monitoring with DIBt certification

The duct smoke detector R-KRM-...-DZ was developed for smoke detection in ventilation ducts. It is a combination of a smoke detector and an adaptor system, its measuring tube and housing were especeally customized for an optimum air flow through the smoke detector.

Outputs:
■ Relay outputs: potential-free
■ Alarm relay locked: 1 change-over contact 250 V, 8 A; 1 break contact 250 V, 6 A
■ Pollution relay: 1 break contact 250 V, 6 A
■ System fault relay: 1 break contact 250 V, 6 A
■ Airflow relay: 1 break contact 250 V, 6 A

Tender Text
EC Declaration of conformity

R-KW-T

Condensation monitor

The condensation monitor is used to detect condensation on chilled ceilings. The monitor registers condensation on the (rear) contact prism. The device contains sensor and evaluation electronics. With signaling LED and relay contact for connection to control and display systems or for series connection with the cooling valve to directly interrupt the cooling water flow in case of incipient condensation.

R-KW1

Dew-point / condensation monitor

The condensation monitor R-KW1 is used for monitoring the condensation on cooling ceilings, for preventing condensation at critical spots in heating-, ventilation- and air conditioning systems and as dew point monitor for plants that are operated near the dew point.

Sensor: Humidity HC105 Protection by special coating (permeable to water vapour)

Outputs: Potential-free relay with changeover contact

Measuring range: 10...100 % rH.

Tender Text
EC Declaration of conformity

R-LDS

Differential power switch for gaseous media

As flow indicators in differential pressure function, the pressure switches of type R-LDS, being installed in air ducts, monitor filters, fans and air dampers in primary / secondary closed-loop controls. Additionally, the pressure switches of type R-LDS are ideally suited for the thermal protection of air heaters or for monitoring industrial cooling air circuits. Medium: air and non-aggressive gases..

Tender Text
EC Declaration of conformity

R-LRS01

Smoke switch system for ventilation duct monitoring

By using the ventilation smoke switch system R-LRS01, smoke can be detected at an early stage. The propagation of smoke in the ventilation system is prevented due to the timely detection. The R-LRS01 can be used in ducts with rectangular and round cross-sections. It is designed for the field of application within buildings.

Tender Text
EC Declaration of conformity

R-RH

Room hygrostat

Suitable for closed- loop control and monitoring of the relative humidity in offices and living areas, bathrooms, laboratories, control cabinets, computer rooms, etc.. Not suitable for aggressive gases.

Sensor: Plastic fibres

Outputs: Switching, 1-level floating change-over contact

Tender Text
EC Declaration of conformity

R-RH...-T

Room hygrostat for controlling the relative humidity

The room hygrostat is used to control (two-point) the relative humidity in offices, computer, business, and storage rooms, etc

R-RS142

Optical smoke switch for room monitoring

The R-RS142 optical smoke switch reacts promptly to smouldering fires as well as to flaming fires that develop smoke. An additional temperature sensor is triggered at an ambient temperature of 70 °C.

Tender Text
EC Declaration of conformity

R-RTR-T

Room thermostat

The flat room thermostat is intended for heating and cooling operation via a 2-wire system in residential, industrial, and business premises. The setpoint temperature is adjusted via the large rotary knob. This sensor can be used for temperature control and as overheating protection.

R-RTS-T

Room temperature controller

One-step mechanical single room controller in bimetal technology with thermal feedback for monitoring or controlling temperatures in dry rooms, or for activating any kind of heating system as room thermostat. For currentless open radiator valves the cooling output from the changeover contact (normally open contact) must be connected. At breaker contacts a maximum of ten valve actuators can be connected and at normally open contacts a maximum of five valve actuators.

Tender Text
EC Declaration of conformity

R-SW

Flow indicator for piping installation

The R-SW-... is a mechanical flow indicator with paddle for piping installation, suitable for flow monitoring of liquid and gaseous media in pipelines, hydraulic systems from 1/2“ up to 8“ diameter, as flow monitor or water-failure safety device, e.g. for pumps in heating and cooling circuits, refrigeration machines, vaporisators, compressors and heat exchangers.

Tender Text
EC Declaration of conformity

R-SWM

Water detector

The electronic water detector serves to monitor containers and rooms.

Sensor: 2x2 Detector electrodes, water conductivity

Outputs: Break contact, LED displays, relay contact max. 1 A, max. 60 V

Tender Text
EC Declaration of conformity

R-TUC

Universal thermostat TW (-10..50°C)

It is applied for controlling and onitoring temperatures of liquids in bathrooms, containers, pipelines and ducts.Due to its modular structure, it can be used as contact thermostat, rod thermostat, double thermostat and as thermostat with remote sensor.Variants as temperature monitors (TW), safety temperature monitors (STW), temperature limiters (TB) or safety temperature limiters (STB).The scope of delivery includes a brass immersion sleeve of 100 mm length.

Tender Text
EC Declaration of conformity

R-WFS-1EPL

Paddle vane relais

The R-WFS-1EPL ist applicable for flow monitoring of gaseous media in ventilation and air conditioning ducts, in air intake and exhaust devices of ventilators or electric heating registers (also for contaminated, oily air), o ras flow controller and airflow monitor.
 

Tender Text
EC Declaration of conformity

T-THM-THN

Immersion sleeves

Immersion sleeves with screw terminal for cable temperature sensor F-KTF1… and screw-in immersion sensor F-ROF1... for installation in hot and cold water networks.

T-THM-THN-T

Immersion sleeves

Immersion sleeves with compression fitting for duct/immersion temperature sensors F-KATF...-T and cable temperature sensors F-KTF-T for mounting in pipes and vessels.

T-THM-THN-TUC

Thermowell for R-TUC

Protective tube: for one univeral thermostat, for a minimum of two thermostats with a Ø 6 mm

Specifications:
■ For installation on pipelines and containers, for integration of sensor cartridges, immersion stems, temperature sensors, temperature controllers of thermostats
■ Made of brass (Ms) or stainless steel (V4A)
■ Types with cylindrical (G½“ A ISO 228/1 flat-sealing) or conial (R½“ ISO 7/1 thread-sealing)1 pipe threads
■ With compression spring